Freedom 5 IID


HOW TO PROVIDE A BREATH SAMPLE

 

A breath sample is provided by blowing a deep lung breath directly into the mouthpiece of the Sensor Head.

 

The AATI Freedom-5 incorporates an audible breath test indicator which is located in the Sensor Head. The indicator provides the driver with feedback as an aid with the breath sample requirements.

 

When the Ignition key is set to the “ON” position or if the engine has been started using the Bypass Switch and the brake pedal is pressed the voice message “PLEASE WAIT” will be heard. Approximately 15 seconds after this the voice message “PLEASE PROVIDE A SAMPLE” will be heard followed by two short audible tones. The breath sample may be provided any time after the two short audible tones.

 

To provide the breath sample, remove the Sensor Head from its location on the dashboard. by lifting it off its hook in a vertical direction.

 

While taking in a deep breath, bring the Sensor Head up to your mouth and place the mouthpiece between your lips. Ensuring that your lips have formed a good seal around the mouthpiece, exhale directly through the mouthpiece. Make sure as you exhale that no air escapes through the side of your lips. Blow with an even firm pressure.

 

The audible tone will start sounding as you start blowing and will continue to sound PROVIDING your breath sample is of sufficient duration and pressure.

 

Continue blowing into the mouthpiece until the continuous tone stops (approximately 6 seconds). After the continuous tone has stopped, two further short tones will be heard which indicate the end of the test. Return the Sensor Head back to its location on the dashboard. on to its hook, pushing down until a positive capture is felt.

 

 

REMOVING THE SENSOR HEAD

 

The Sensor Head can be removed from the vehicle providing an effective anti theft feature since the vehicle cannot be started without the sensor head. To disconnect the Sensor Head, gently pull the ring on the connector located on the end of the coiled cord while holding the connector coming from the Control Module. To connect the Sensor Head bring the two connectors together while slowly rotating one until they engage. Continue gently pushing both connectors together until they are seated.

 

CARING FOR THE AATI Freedom-5 SYSTEM

 

The only user maintenance required is the occasional replacement of the mouthpiece. Replace the mouthpiece with a new one if you see excessive liquid in the trap area. New mouthpieces are available from AATI.spare mouthpieces in different colors are supplied.

 

WARNING – UNDER NO CIRCUMSTANCES SHOULD YOU WASH THE COMPLETE SENSOR HEAD OR ALLOW IT TO COME INTO DIRECT CONTACT WITH LIQUIDS. ONLY USE A MOIST CLOTH TO GENTLY WIPE THE SENSOR HEAD CASING. DO NOT USE DETERGENTS.